EcoWallter with Type 2 cable
- Cable 6.5, 10 or 15 m, longer on request
- Optional Tesla button
- 11 or 22 kW
- MID metering circuit and RFID in the base version
- Integrated type B residual current device
- Integrated under-voltage and over-voltage protection
A wallbox that can charge from PV surplus. Suited to fleets thanks to clear functions.


Only a certified electrician. A verification measurement and an inspection report are required before start-up. We install across the Czech Republic.
A dedicated supply (11 kW 5x4 mm², 22 kW 5x6 mm²), a 3x 16 A or 3x 32 A type B curve breaker and an upstream type A residual current device. The type B RCD is integrated in the wallbox. We recommend running two UTP/FTP data cables.
The tethered Type 2 cable (6.5, 10 or 15 m) is more convenient for one car. The Type 2 socket suits places where several cars charge with their own cable.
Yes. The MID certified metering circuit and RFID reader serve internal cost allocation. Billing electricity to third parties needs a separate verified meter.
EcoWallter is built to order, delivery within 2 weeks.
| Type | Fixed Mode 3 wallbox, protection class I |
|---|---|
| Power | 11 kW (3x 16 A) or 22 kW (3x 32 A); current 6 to 32 A in 1 A steps |
| Versions | Tethered Type 2 cable 6.5 / 10 / 15 m (longer on request) or Type 2 socket |
| Metering | MID certified metering circuit in every unit, for internal cost allocation |
| Protection | Integrated type B RCD with self-test, phase detection, over and under voltage, N and PE check, welded relay protection, temperature monitoring |
| Connectivity | Bluetooth (standard), Wi-Fi, Wi-Fi + LTE; Ethernet on Wi-Fi variants |
| RFID | Reader included in all variants |
| Ingress and operation | IP54, operating temperature -25 to +45 °C |
| Dimensions | 280 x 315 x 110 mm, steel enclosure, 4 to 6.8 kg depending on variant |
| Conformity | EU declaration of conformity (CE, RoHS, RED) |
Manuals are in the download section.